Showing posts with label Dyna concept. Show all posts
Showing posts with label Dyna concept. Show all posts

Thursday, July 11, 2013

DYNA OCTALOCK

DYNA OCTALOCK 
Dyna Dental Engineering has always been on the spearhead of the innovative
solutions for dental implantology. We strive constantly to improve our products in order to
supply clinicians, practising dentists and dental technicians with up-to-date solutions.
During the years we have developed a unique implant philosophy, based on the
clinical experience of the users. The guarantee of the highest possible standards of quality
and production process is complying with ISO 9001 and authorisation to issue all of our
products with CE symbol.
In response to still growing demands of dentists worldwide we decided to broaden
our product line with the revolutionary Dyna Octalock System, aimed at improving fixed
prosthodontics.
Years of experience gave us the confidence to design a connection system between
the implant and the implant abutment, that would provide the dentist with a reliable tool for
crown and bridge works. Our philosophy to keep all the procedures simple made us choose
for the already existing outside design of the implant itself, and completely changed, new
range of prosthetic abutments. Due to such combination it was possible to join a very simple
surgery with an easy and reliable prosthetic part. A variety of prosthetic treatment options
can be undertaken using the Octalock implants as anchorage component. The octagonal
connection besides superior antirotation increases the strength of the implant wall and gives
more freedom during prosthetic construction. Last but not least improved aesthetics was an
issue during the development of the Octalock connection.
The system combines flexibility , simplicity and reliability with cost effectiveness
and high quality of all used materials. It meets both demands of the surgeons and patients
and allows to look forward to undisturbed functioning and long term

Fixture
The Dyna implant has been extensively documented and
clinically used since 1986. Complication-reducing simplicity of
surgical and prosthetic procedures, has confirmed easy and
predictable treatment option. The HA-coated, two stage implant
based on the push-in principle requires a minimum of
instrumentation and presents no special difficulty in application
technique. The combination of a cylinder shape with rounded
1601-01.04 Dyna Pushin Implant Manual GB 19 / 144
threads provides excellent biomechanical properties. A high strength of the implants
is guaranteed for all diameters by the use of grade 5 titanium.
The HA coating is firmly connected to the titanium implant body so the risk of
mechanical fracture is neglectable. Excellent bone bonding properties of the HA
(especially in poor bone quality) are assured by using the best quality HA powder and
controlled process of plasma spraying. The uniform layer of HA has a fixed
crystalline ratio and therefore optimal bio-chemical properties.
Based on the biological width principle besides coated up to the neck implants
they are available with a machined polished collar.
The implant is available in three diameters 3.6mm, 4.0 and 5.0mm, and different
lengths (from 8 to 15). It is intended to cover the majority of clinical situations, but
most of all to be reliable and user-friendly in fixed prosthodontics.
Every implant is supplied together with the covering screw in sterile, double
peel-pouch type packaging
.

 








HA surface in SEM
The new attribute of the Octalock system is completely changed inside
connection with the abutment. In comparison with the old system it has the following
new features:
 a conical fixation screw
 a conical abutment connection
 an internal octagon
The Octalock connection between the implant and abutment has been developed
to broaden the existing Dyna Implant System. Based on the experiences of the
researches and clinicians, it is aimed at improving, and at the same time facilitating,
fixed prosthodontics. As an outcome of the interdisciplinary cooperation it joins the
best biomechanical features. The use of only two implant diameters and all-fit
abutments gives an interesting combination of simplicity and reliability.
Instruments
Instruments manufactured by Dyna Dental BV are
designed to be simple and universal. Only a limited number
of instruments are sufficient to perform surgery phase and
complete prosthetic part. Selection of drills corresponding
with the diameters and lengths of implants enables precise
preparation of the implant bed in a time-saving and possibly
atraumatic manner.
All instruments, however, should be regularly checked by
the user to see that they are working properly


Abutment

For cemented as well as screwed fixed prostheses on Dyna Octalock implants,
several innovative abutment systems are available. These are developed according to the
latest standards. Optimalised aesthetics can be obtained with a range of abutments that can
be individualised in the lab. Octalock connection between Dyna implant and its abutment
represents a design which stands for real antirotation. The risk of loosening the abutment
is virtually prevented thanks to special features of this connection, thereby insuring
mechanical strength and long-term stability.
The collection of lengths combined with universal abutment design allow for individual
solutions and treatment variation, being user-friendly at the same time.
The new abutment line of the Octalock System consist of the abutment itself and
the fixation screw.
1601-01.04 Dyna Pushin Implant Manual GB 21 / 144
The same abutments may be used for diameters 3.6, 4.0 and 5.0mm implants, and there is only one
fixation screw that can be used for both diameters and all abutments heights.
Such solution in combination with the Octalock connection has the following advantages:
 stable and secure connection
 simplified prosthetic procedure
 precise impression
 significantly shorter and easier treatment time
 creating a very simple system
 reduction of stock
 reduction of costs

In comparison to our old all-in-one abutment, the new line of products allows for working
on the same abutment in the lab and in the mouth of the patient. Exact and easy transfer of
the implant position to the model eliminates the need to use abutment analogues and
increases the transfer precision. The conical connection and conical head of the fixation
screw protects both the screw and the abutments from overloading and makes the force
distribution more uniform.
New abutments have been developed baring in mind conventional fixed prosthodontics for
teeth. They are more solid and have chamfer finish allowing for excellent production of
ceramic crowns. The chamfer line is also more exposed (in comparison with the old
system) in order to allow for taking conventional impressions over the abutment*.
Abutments can also be individualized by the technician to get the best aesthetic results.
*Dyna Dental recommends open tray technique
Read More

Wednesday, July 10, 2013

Dyna Concept (Introduction)

DYNA IMPLANT
Dyna Implant System is the complete implant system made totally in Holland
able to solve wide range of implant-related clinical indications. It has been developed in
close cooperation with the Open University of Amsterdam and the University Leiden and it
was the first system with HA coated implants commercially available on the world market.
Years of clinical experience supported by
numerous studies carried out on different universities have proved that proposed by Dyna
Dental Engineering concept of simplified implantation technique leads to excellent and
predictable results.
The system combines flexibility, simplicity and reliability with cost effectiveness and high
quality of all used materials. It meets both demands of surgeons and patients and allows to
look forward to undisturbed functioning and long term success.

Fixture
The implant is HA coated full titanium cylinder with reversed screw designed to give
secure mechanical fixation and load distribution. It is two a stage, push-in type implant.
HA covering promotes the process of bone ingrowth not only from the bone side but from the fixture
surface as well.
The implant is available in four diameters (including Ø3mm), and different lengths allowing for
using the system in situations, where the amount of available bone is limited.
Every implant is totally covered (without polished collar) with a thin layer of hydroxylapatite, which
creates anchoring surface favouring direct bone apposition.
Every implant is supplied together with the covering screw in sterile double peel-pouch type
packaging

Abutment
The abutment is an all-in-one element without separate fixation screw.
This solution simplifies the procedure and necessary instrumentation.
There are several types of abutments for all types of prosthetic constructions
available.



Instruments
Instruments manufactured by Dyna Dental BV
are designed to be simple and universal. Only a limited
number of instruments are sufficient to perform surgery
phase and complete prosthetic part. Selection of drills
corresponding with the diameters and lengths of implants
enables precise preparation of the implant bed in a timesaving
and possibly atraumatic manner.
All instruments, however, should be regularly checked
by the user to see that they are working properly.

Dyna philosophy
Dyna Dental BV is present on the dental market since 1984. During this time a special
philosophy was formulated. It can be seen as a principle for the use of Dyna System.
Besides the well accepted rule of using the biggest implant that can be placed in all situations
it is important to determine, before implantation, the type of the prosthetic construction you wish to
construct.
Indeed, there are numerous possibilities but, in fact, the real choice you have to make is the
choice between the removable, and not removable prosthesis.
1601-01.04 Dyna Pushin Implant Manual GB 17 / 144
removable prosthesis can be taken out of the patients mouth in a simple manner by the patient
himself or by the dentist.
By using the Dyna System it is possible to construct a full range of overdentures. The following
anchoring possibilities are available:
-the magnet
-the bar
-the ball
not removable prosthesis is a construction that can’t be removed by the patient and the dentist
needs special prosthetic instrumentation. In general cemented or screwed retained crowns and
bridges are the most popular.
Example abutments for this type of constructions are:
-bar abutment
-memory abutment
-fixed crown abutment
Every construction should be scrupulously analysed and a full individual treatment plan prepared.
For removable prostheses we recommend using implants
-with diameter smaller then Ø4.0;
whereas for non removable prostheses implants
-bigger or equal Ø3.6 [only in exceptional situations is it allowed to use Ø3.0 implants but
with the length not shorter than 13mm]
For almost all prosthetic constructions Ø3.6 implant is the most universal one;
Ø3.0 6mm-long implant is available only for maxillo-facial purposes

Important features of the system
Dyna Implant System has following advantages:Individual choice of implants
  •  Wide range of indications
  •  Standardized instrumentation
  •  Standardized implant design
  •  Simple surgical and prosthetic procedure
  • Time saving.

Read More
Powered By Blogger · Designed By Seo Blogger Templates